ACB Maintenance/Service And Testing

Air Circuit Breaker (ACB) Maintenance

To ensure your equipment operates reliably we recommend an appropriate maintenance plan. We attend sites for regular maintenance and also for emergencies when an ACB is not functioning correctly.

Schedules to suit you and your site

Each site and ACB is different. This means a service schedule is to be assessed after a discussion or visit with you. The schedule depends on the environment the ACBs operate in and how often they operate – too little use causes as much need for maintenance as excessive use.

Our service plan enables us to service your breaker in situ if fixed or withdrawable or to remove and work on it at our premises. During the service we disassemble certain elements of the ACB to allow inspection, lubrication, repair and testing. We have a range of specialized secondary injection test equipment to enable us to test the operation of the ACBs electronic trip units and their parameters.

Distribution & Control Panel Maintenance

We also offer a complimentary service for your distribution/ control panels. We recommend periodically that the panels are cleaned inside and out to remove dirt and dust. At the same time the switchgear connections can be checked and tightened and the supply and distribution busbar connections can be re-torqued. We have seen many instances where dirt on busbars and loose connections can cause noise, excessive heat and ultimately system failure due to lack of maintenance.

Common faults we see:

  • Air Circuit Breaker will not open (turn ‘OFF’)
  • Air Circuit Breaker will not close (turn ‘ON’)
  • Air Circuit Breaker will not charge up/ reset
  • Air Circuit Breaker won’t trip off as set or required
  • Air Circuit Breaker won’t stay closed when turned on
  • Erratic / nuisance tripping off of the Air Circuit Breaker

Most of these common faults can be avoided by an appropriate service schedule.

ACB service in Lucknow and across UP

ACB maintenance, testing and trip-unit checks done properly

An air circuit breaker protects your whole LT system. If its trip unit is out of setting, or its contacts are worn, it may not trip when it must, or trip when it should not. Our engineers service and test ACBs on site, in fixed and draw-out versions, and leave you with a written test report.

We service all major makes of LV air circuit breakers. Where a breaker is obsolete and spares are no longer made, we can retrofit a new breaker into your existing panel.

Tajalli Tech engineers testing an ACB trip unit with a secondary injection kit

What our ACB service includes

  • Visual inspection and cleaning of the breaker and cradle
  • Main and arcing contact inspection and wear check
  • Arc chute inspection
  • Mechanism cleaning and lubrication
  • Closing and tripping coil checks
  • Spring charging motor check
  • Insulation resistance test
  • Contact resistance test
  • Secondary injection test of the trip unit
  • Protection settings checked against your coordination
  • Interlock and racking mechanism check
  • Written test report with readings and advice

How often should an ACB be serviced?

Site conditionRecommended service
Clean electrical room, few operationsOnce a year
Dusty, humid or corrosive area (cement, chemicals, textiles)Every 6 months
Breaker has tripped on a short circuit or heavy faultInspect before putting it back in service
Breaker not operated for a long timeService and operate it, idle breakers also need care

We agree the schedule with you after a site visit, based on the breaker, the duty and the environment.

How we work

1

Site visit

We note make, rating, settings and condition of each ACB.

2

Plan the shutdown

We agree a date and time that suits your production.

3

Service and test

Cleaning, lubrication, contact checks, IR and trip-unit tests.

4

Report

You get readings, photos and our recommendations.

Why Tajalli Tech

Since 2016Class-A licensed electrical contractor based in Aliganj, Lucknow.
Calibrated test kitsOur own instruments, with a written report after every job.
ISO 9001:2015Documented quality process, and a Schneider Electric EcoXpert partner for LV services.

Questions

Can the ACB be serviced at our site?

Yes. Most ACBs are serviced on site. A draw-out ACB is racked out and serviced next to the panel. A fixed ACB is serviced in place during a planned shutdown.

What is secondary injection testing of an ACB?

It checks the electronic trip unit by injecting a test current from a portable kit. It confirms that long-time, short-time, instantaneous and earth-fault protection trip at the right values and times.

How long does the shutdown take?

Usually a few hours per breaker. We plan the work with you so production is affected as little as possible.

Our ACB is very old and spares are not available. What can we do?

We can retrofit a new breaker into the existing panel, which costs less than a new panel. As a Schneider Electric EcoXpert partner for LV services we use genuine parts. See ACB retrofit.

Book an ACB service visit

Tell us how many breakers you have and where. We will plan the visit and send a quote.

Related: ACB services in Lucknow · VCB maintenance and testing · Secondary injection testing · Schneider EcoXpert LV services · Service packages and AMC